WALL SYSTEM - STC 81 |
 |
CONSTRUCTION ASSEMBLY |
| ITEM A: |
200 mm steel C-Channels, 2.0 mm thick used as horizontal girths, fixed to structural columns at 300 mm vertical centres. |
| ITEM B: |
1 layer of 16 mm plasterboard fixed to one flange of Item A |
| ITEM C: |
92 mm Rondo steel studs, at 600 mm staggered centres, resilient rubber mounted to both faces of Item A. One set of studs is fixed through 16 mm plasterboard (Item B) |
| ITEM D: |
Both faces of 16 mm plasterboard (Item B) are sprayed with nominal 50 mm thick ENVIROSPRAY 300. |
| ITEM E: |
After adequate curing time for applied ENVIROSPRAY 300 (Item D), 2 layers of 16 mm plasterboard are fixed to both sides of 92 mm staggered studs (Item C) |
|
- Test Conducted at National Acoustic Laboratories - Sydney
- Test Report No : ATF 408
|
|
|
|
|
 |
 |