ENVIRO ACOUSTICS PTY. LTD
NEWS PRODUCTS FAQS PROJECTS SPECIFICATION TESTED SYSTEMS CONTACT US HOME
Tested Systems
Tested Systems
Wall System STC 84

Wall System STC 81

Wall System STC 77

Wall System STC 66

Wall System STC 47

Wall System STC 36

Wall System STC 32

Wall System STC 28

WALL SYSTEM - STC 66

WALL SYSTEM - STC 66

CONSTRUCTION ASSEMBLY

ITEM A: 0.6mm BMT Colorbond metal external cladding is fixed to 28mm furring channels, themselves fixed to 200 mm C-Channels horizontal girths. Girths are spaced at 600 vertical centres.
ITEM B: Internal face of metal cladding is sprayed with nominal 100mm thick ENVIROSPRAY 300
ITEM C: Structural adequacy is provided by 360UB structural steel columns located within air space of 628mm between external cladding and internal face of Hebel block wall (Item D).
ITEM D: 150 mm thick Hebel aerated concrete wall, density 600 kg/m3, mechanically tied to steel columns (Item C)

  • Test Conducted at National Acoustic Laboratories - Sydney

  • Test Report No : E 2691